Availability: | |
---|---|
Quantity: | |
1.Designed for Zone 1 and Zone 2 explosive atmosphere.
2.Designed for IIA,IIB,IIC groups explosive atmosphere.
3.Designed for the environment with T1~T5 temperature class
4.Designed for explosive atmosphere, such as oil extraction refining, storage, chemical, pharmaceutical, military and military facilities, etc.
5.Can control 2 or 3 circuit be on and off.
1.Designed for Zone 1 and Zone 2 explosive atmosphere.
2.Designed for IIA,IIB,IIC groups explosive atmosphere.
3.Designed for the environment with T1~T5 temperature class
4.Designed for explosive atmosphere, such as oil extraction refining, storage, chemical, pharmaceutical, military and military facilities, etc.
5.Can control 2 or 3 circuit be on and off.
1.Enclosure is of glass reinforced polyester with increased safety structure
with several high performances ,such as corrosion resistance , impact resistance and good thermal reliability ,etc.
2.Labyrinth sealing structure design and with the functions of waterproof and dustproof.
3.Built-in flameproof type switch. 2-pole and 3-pole are options.
4.Steel pipe wiring and cable wiring.
1.Enclosure is of glass reinforced polyester with increased safety structure
with several high performances ,such as corrosion resistance , impact resistance and good thermal reliability ,etc.
2.Labyrinth sealing structure design and with the functions of waterproof and dustproof.
3.Built-in flameproof type switch. 2-pole and 3-pole are options.
4.Steel pipe wiring and cable wiring.
1.Rated voltage:AC220V/380V ,as per requirement
2.Rated current:16A~63A,or as per requirement
3.Ingress thread specification:G3/4"/G1"/G1 1/2"
4.Cable's outer dia:9mm~18mm
5.Inlet number:2
6.Explosion protection:ExedIICT5
7.Ingress protection:IP65
8.Corrosion resistance:WF2
9.Compliance with :GB 3836.1,GB 3836.2,GB 3836.3,IEC60079-0,IEC60079-1,IEC60079-7
Type | Rated voltage (v) | Rated current (A) | Cables outer diameter (φ,mm) | Ex-mark | Inlets thread(G") | Inlets No. |
BZZ8050-16 | 220/380 50Hz | 16 | 9~14 | Exed IIBT5 Exed IICT5 | 3/4 | 2 |
BZZ8050-32 | 32 | 11~18 | 1 | 2 | ||
BZZ8050-63 | 63 | 17~28 | 11/2 | 2 |
1.Rated voltage:AC220V/380V ,as per requirement
2.Rated current:16A~63A,or as per requirement
3.Ingress thread specification:G3/4"/G1"/G1 1/2"
4.Cable's outer dia:9mm~18mm
5.Inlet number:2
6.Explosion protection:ExedIICT5
7.Ingress protection:IP65
8.Corrosion resistance:WF2
9.Compliance with :GB 3836.1,GB 3836.2,GB 3836.3,IEC60079-0,IEC60079-1,IEC60079-7
Type | Rated voltage (v) | Rated current (A) | Cables outer diameter (φ,mm) | Ex-mark | Inlets thread(G") | Inlets No. |
BZZ8050-16 | 220/380 50Hz | 16 | 9~14 | Exed IIBT5 Exed IICT5 | 3/4 | 2 |
BZZ8050-32 | 32 | 11~18 | 1 | 2 | ||
BZZ8050-63 | 63 | 17~28 | 11/2 | 2 |